实现Ethernet Modbus Tcp 与外设通讯上传至物联网服务器。
提示:本项目的开发只是应用集成。
硬件配置
主控MCU: ESP32-WROOM-32
Ethernet 模块: W5500
4G模块: Air780E
电源模块: 输入:4.7-40 VDC 输出 5V
开发环境
Aruino 2.1.1
MQTT服务器: Moisquito
Modbus Tcp Slave 模拟器。
可以参考文章
MQTT服务器 Mosquitto的部署和应用
可以参考如下连接http://wiki.waaax.cn/MODULE/GSM/AIR780EX/AIR780EX.html
ESP32和Air780串口通讯。(如何需要用电脑监控该串口指令,需要TTL模块)
VIN ->5V DC
V_MCU->3,3VDC
GND -> GND
TXD -> P16(UTRA2_RX)
RXD->P17(UTRA2_TX
右边 PWK 和GND 短接
SPI接口连接
ESP32 对应接口如下:
ESP32_MOSI 23
ESP32_MISO 19
ESP32_SCK 18
ESP32_CS 5
项目中所应用第三方库 modbus-esp8266,感谢大神提供
https://github.com/emelianov/modbus-esp8266
IPAddress mdIp; // Address of Modbus Slave device //ModbusIP mb; ModbusEthernet mb; //初始化 modbus tcp void initMbTcpMaster() { Serial.print("Init Modbus Tcp:"); mb.client(); if (String(mb_slave_ip).indexOf("*") < 0) { Serial.println(mb_slave_ip); mdIp.fromString(mb_slave_ip); } else { Serial.println("192.168.1.254"); mdIp.fromString("192.168.1.254"); } } //初始化ETHERNET void initEthernet() { Serial.print("Initialize Ethernet:"); Ethernet.init(ESP32_CS); // CS pin 5 if (Ethernet.begin(mac,10000,4000) == 0) { // // Check for Ethernet hardware present if (Ethernet.hardwareStatus() == EthernetNoHardware) { Serial.println("Ethernet shield was not found. Sorry, can't run without hardware. :("); return; } if (Ethernet.linkStatus() == LinkOFF) { Serial.println("Ethernet cable is not connected."); } if (String(ethernet_ip).indexOf("*") < 0) { IPAddress ethernetIp; ethernetIp.fromString(ethernet_ip); Ethernet.begin(mac, ethernetIp); // use DHCP } } // start the server Serial.println(Ethernet.localIP()); } // 初始化4G模块 bool init780E() { Serial.println("init Air780E:"); // 确认模块是否通讯上 if (sendCommand("AT\r\n", "OK\r\n", 3000, 10) != Success){ // Handle AT delay(500); return false; } if (sendCommand("AT\r\n", "OK\r\n", 3000, 10) == Success); else { errorLog(1); return false;} // 恢复出厂设置 if (sendCommand("AT&F\r\n", "OK\r\n", 3000, 10) == Success); else {errorLog(2);} // 检查网络信号强度 if (sendCommand("AT+CSQ\r\n", "OK\r\n", 3000, 10) == Success); else {errorLog(3); return false;} delay(100); // 检查sim卡是否被识别 if (sendCommandReceive2Keyword("AT+CPIN?\r\n", "READY","OK\r\n" ,3000, 10) == Success); else {errorLog(4); return false;} delay(100); // 查询运营商 if (sendCommand("AT+COPS?\r\n", "OK\r\n", 3000, 10) == Success); else {errorLog(5); return false;} delay(100); if (sendCommandReceive2Keyword("AT+CREG?\r\n", ",1","OK\r\n", 3000, 10) == Success); //本地SIM卡 else if(sendCommandReceive2Keyword("AT+CREG?\r\n", ",5", "OK\r\n",3000, 10) == Success );//漫游SIM卡 else {errorLog(6); return false;} // 链接断链后重连 if (sendCommand("AT+CIPSHUT\r\n", "OK\r\n", 5000, 10) == Success); else {errorLog(7); return false;} // 查询网络是否激活 if (sendCommandReceive2Keyword("AT+CGATT?\r\n", "+CGATT: 1","OK\r\n" ,3000, 10) == Success); else {errorLog(8); return false;} delay(100); if (sendCommand("AT+CSTT\r\n", "OK\r\n", 3000, 10) == Success); else {errorLog(9); return false;} delay(100); if (sendCommand("AT+CIICR\r\n", "OK\r\n", 3000, 10) == Success); else {errorLog(10); return false;} delay(100); if (sendCommandReceive2Keyword("AT+CIFSR\r\n", ".","\r\n" ,3000, 10) == Success); else {errorLog(11); return false;} delay(100); Serial.println(" init Air780E: OK"); return true; }
// 读取modbus tcp数据 // mb_hold_regs 是开放变量用于设置读取的寄存器地址例如:1,2,3,4, 就是读取1、2、3、4号寄存器地址的内容 String mdRead() { String result = ""; uint16_t res[225]; int in = 0; if (mb.isConnected(mdIp)) { // Check if connection to Modbus Slave is established String token = String(mb_hold_regs); while (true) { // 循环遍历每个子串 int idx = token.indexOf(","); if (idx >= 0) { uint16_t ret = 0; uint16_t addr = token.substring(0, idx).toInt(); ret = mb.readHreg(mdIp, addr, &res[in], 1, nullptr, mb_slave_id); // Initiate Read Coil from Modbus Slave mb.task(); token = token.substring(idx + 1, token.length()); in++; } else break; } } else { mb.connect(mdIp, 502); // Try to connect if no connection Serial.println("modbus connecting"); // Common local Modbus task mbInit = true; delay(5000); return ""; } // Common local Modbus task mb.task(); if(mbInit){ mbInit = false; return ""; } for (int i = 0; i < in; i++) result += (String(res[i]) + ","); if (result != "") Serial.printf("modebus read:%s\n", result.c_str()); return result; }
void mqttSend4G(String msg) { if (msg == "") return; if (mqttConnected == false) { Serial.printf("Mqtt server connect %s\n", mqtt_server); connectMQTTServer(); } if (mqttConnected) { Serial.printf("send mqtt message topic: %s,value: %s\n", mqttTopic.c_str(), msg.c_str()); publishDataToServer(msg); } } void publishDataToServer(String msg) { char send_buf[150] = {0}; char tmp[100] = {0}; char value_str[15] = {0}; memset(send_buf, 0, 150); //清空 memset(tmp, 0, 100); //清空 strcat(send_buf, "AT+MPUB=\""); strcat(send_buf, mqttTopic.c_str()); strcat(send_buf, "\", 0, 0,\""); strcat(send_buf, msg.c_str()); strcat(send_buf, "\"\r\n"); if (sendCommand(send_buf ,"OK\r\n",3000, 10) == Success); else errorLog(1); } void connectMQTTServer() { if(!init780E()) return; char send_buf[100] = {0}; memset(send_buf, 0, 100); //清空 strcpy(send_buf, "AT+MCONFIG=\""); strcat(send_buf, serial); strcat(send_buf, "\",\""); strcat(send_buf, mqtt_user); strcat(send_buf, "\",\""); strcat(send_buf, mqtt_password); strcat(send_buf, "\"\r\n"); if (sendCommand(send_buf, "OK\r\n", 8000, 5) == Success); else {errorLog(12); return;} memset(send_buf, 0, 100); //清空 strcpy(send_buf, "AT+MIPSTART=\""); strcat(send_buf, mqtt_server); strcat(send_buf, "\",\""); strcat(send_buf, String(portNumber).c_str()); strcat(send_buf, "\"\r\n"); if (sendCommand(send_buf, "OK\r\n", 8000, 5) == Success); else {errorLog(13);return;} if (sendCommand("AT+MCONNECT=0,80\r\n", "ALREADY CONNECT", 10000, 1) == Success); else { errorLog(14); if (sendCommand("AT+MCONNECT=0,80\r\n", "OK\r\n", 10000, 1) != Success){ errorLog(15); return; } } mqttConnected = true; delay(100); } void(* resetFunc) (void) = 0; //制造重启命令 void errorLog(int num) { Serial.print("ERROR"); Serial.println(num); mqttConnected = false; } unsigned int sendCommand(char *Command, char *Response, unsigned long Timeout, unsigned char Retry){ clrair780RxBuffer(); for (unsigned char n = 0; n < Retry; n++){ Serial.print("send AT Command:"); Serial.println(Command); Serial2.print(Command); Time_Cont = 0; while (Time_Cont++ < Timeout) { delay(1); air780ReadBuffer(); // Serial.print("."); //1.8.x的IDE不加这个会有bug if (strstr(air780RxBuffer, Response) != NULL){ Serial.print("receive AT Command:"); Serial.println(air780RxBuffer); //输出接收到的信息 clrair780RxBuffer(); return Success; } } Time_Cont = 0; } Serial.print("receive AT Command:"); Serial.println(air780RxBuffer);//输出接收到的信息 clrair780RxBuffer(); return Failure; } unsigned int sendCommandReceive2Keyword(char *Command, char *Response, char *Response2, unsigned long Timeout, unsigned char Retry) { clrair780RxBuffer(); for (unsigned char n = 0; n < Retry; n++) { Serial.print("send AT Command:"); Serial.println(Command); Serial2.write(Command); Time_Cont = 0; while (Time_Cont++ < Timeout) { delay(1); air780ReadBuffer(); // Serial.print("."); //1.8.x的IDE不加这个会有bug if (strstr(air780RxBuffer, Response) != NULL && strstr(air780RxBuffer, Response2) != NULL){ Serial.print("receive AT Command:"); Serial.println(air780RxBuffer); //输出接收到的信息 clrair780RxBuffer(); return Success; } } Time_Cont = 0; } Serial.print("receive AT Command:"); Serial.println(air780RxBuffer);//输出接收到的信息 clrair780RxBuffer(); return Failure; } void air780ReadBuffer() { while (Serial2.available()) { air780RxBuffer[air780BufferCount++] = Serial2.read(); if (air780BufferCount == AirRxBufferLength)clrair780RxBuffer(); } } void clrair780RxBuffer(void) { memset(air780RxBuffer, 0, AirRxBufferLength); //清空 air780BufferCount = 0; }
串口打印出发送信息
MQTT.FX监控发布内容
调试4G模块时,使用AT指令时,可能会又报警信息,附上AT 错误列表如下。
摘抄自https://momoiot.co.kr/catm-at/cmd/cme-error-codes/
Final result code +CME ERROR: indicates an error related to mobile equipment or network.
values used by common messaging commands:
Code of Meaning
0 phone failure
1 no connection to phone
2 phone-adaptor link reserved
3 operation not allowed
4 operation not supported
5 PH-SIM PIN required
6 PH-FSIM PIN required
7 PH-FSIM PUK required
10 SIM not inserted
11 SIM PIN required
12 SIM PUK required
13 SIM failure
14 SIM busy
15 SIM wrong
16 incorrect password
17 SIM PIN2 required
18 SIM PUK2 required
20 memory full
21 invalid index
22 not found
23 memory failure
24 text string too long
25 invalid characters in text string
26 dial string too long
27 invalid characters in dial string
30 no network service
31 network timeout
32 network not allowed – emergency call only
40 network personalization PIN required
41 network personalization PUK required
42 network subset personalization PIN required
43 network subset personalization PUK required
44 service provider personalization PIN required
45 service provider personalization PUK required
46 corporate personalization PIN required
47 corporate personalization PUK required
99 resource limitation
100 unknown
103 Illegal MS
106 Illegal ME
107 GPRS services not allowed
111 PLMN not allowed
112 Location area not allowed
113 Roaming not allowed in this location area
132 service option not supported
133 requested service option not subscribed
134 service option temporarily out of order
148 unspecified GPRS error
149 PDP authentication failure
150 invalid mobile class
160 DNS resolve failed
161 Socket open failed
171 MMS task is busy now
172 The MMS data is oversize
173 The operation is overtime
174 There is no MMS receiver
175 The storage for address is full
176 Not find the address
177 The connection to network is failed
178 Failed to read push message
179 This is not a push message
180 gprs is not attached
181 tcpip stack is busy
182 The MMS storage is full
183 The box is empty
184 failed to save MMS
185 It is in edit mode
186 It is not in edit mode
187 No content in the buffer
188 Not find the file
189 Failed to receive MMS
190 Failed to read MMS
191 Not M-Notification.ind
192 The MMS enclosure is full
193 Unknown
600 No Error
601 Unrecognized Command
602 Return Value Error
603 Syntax Error
604 Unspecified Error
605 Data Transfer Already
606 Action Already
607 Not At Cmd
608 Multi Cmd too long
609 Abort Cops
610 No Call Disc
611 BT SAP Undefined
612 BT SAP Not Accessible
613 BT SAP Card Removed
614 AT Not Allowed By Customer
753 missing required cmd parameter
754 invalid SIM command
755 invalid File Id
756 missing required P1/2/3 parameter
757 invalid P1/2/3 parameter
758 missing required command data
759 invalid characters in command data
765 Invalid input value
766 Unsupported mode
767 Operation failed
768 Mux already running
769 Unable to get control
770 SIM network reject
771 Call setup in progress
772 SIM powered down
773 SIM file not present
791 Param count not enough
792 Param count beyond
793 Param value range beyond
794 Param type not match
795 Param format invalid
796 Get a null param
797 CFUN state is 0 or 4
代码无国界,世界上有很多愿意奉献的程序员,但是少有愿意奉献的商人。能GOOGLE,尽量GOOGLE吧。
Copyright © 2003-2013 www.wpsshop.cn 版权所有,并保留所有权利。