赞
踩
DELL R710服务器,二个硬盘做了RAID1,安装系统,四个硬盘(1.2T ST1200MM0007)做了RAID5。
现RAID5其中一个硬盘亮黄灯,购买了一只新的硬盘(1.2T ST1200MM0088)更换上去,结果硬盘灯 黄灯和绿灯交替不断亮,没停过。
重启开机,按CTRL+R进RAID卡设置,看到新硬盘显示:MISSING。此硬盘状态也是显示为:Failed,而不是ONLINE。
请问怎么把新硬盘重新添加进去RAID5???
警报日志
严重性 ID 日期和时间 类别 说明
2080 Mon Oct 30 14:19:35 2017 Storage Service Physical disk Initialization failed: Physical Disk 1:0:4 Controller 0,
Connector 1
2405 Mon Oct 30 14:19:34 2017 Storage Service Command timeout on physical disk: Physical Disk 0:0:4 Controller 0,
Connector 0
2052 Mon Oct 30 14:19:34 2017 Storage Service Physical device inserted: Physical Disk 1:0:4 Controller 0, Connector 1
2405 Mon Oct 30 14:19:03 2017 Storage Service Command timeout on physical disk: Physical Disk 0:0:4 Controller 0,
Connector 0
2049 Mon Oct 30 14:18:16 2017 Storage Service Physical device removed: Physical Disk 1:0:4 Controller 0, Connector 1
2048 Mon Oct 30 14:18:16 2017 Storage Service Device failed: Physical Disk 0:0:4 Controller 0, Connector 0
1552 Mon Oct 30 14:17:39 2017 Instrumentation Service Log size is no longer near or at capacity Log type: ESM
0 Mon Oct 30 14:16:42 2017 Instrumentation Service Log was cleared