Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1A10
PDBPwrCable
High
PDB power cable to the planar is missing or bad and system will not power on.
Failing device is reseated/replaced/repaired.
Yes
Pre-Post
E1A11
PCIRsrConfig
High
PCI risers are not configured correctly; some invalid configurations prevent system power on.
Failing device is reseated/replaced/repaired.
Yes
Pre-Post
E1A12
PCIRsrMissing
High
One or all of the PCI risers is missing. This prevents system power on.
Failing device is reseated/replaced/repaired.
Yes
Pre-Post
E1A14
SAS Cable A
Low
SAS cable A is missing or bad.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A15
SAS Cable B
Low
SAS cable B is missing or bad.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A16
SAS Cable FB
Low
Flex bay SAS cable is missing or bad.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A17
PwrCable FB
Low
Flex bay power cable is missing or bad.
Failing device is reseated/replaced/repaired.
Yes
Any
E1A18
PDBCtrl Cable
High
PDB control cable to the planar is missing or bad and system will not power on.
Failing device is reseated/replaced/repaired.
Yes
Any
Temperature - Message Code: "x11xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1114
Temp Ambient
Med
Ambient temperature has a reached a point outside of the allowed range.
Temperature returns to allowable range.
Yes
Any
E1116
Temp Memory
High
Memory has exceeded allowable temperature and has been disabled to prevent damage to the components.
AC Cycle or SEL clear
Yes
Any
Voltages - Message Code: "x12xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1210
CMOSBatt
Low
CMOS battery is missing or the voltage is outside of the allowable range.
Failing device is reseated/replaced/repaired.
Yes
Any
E1211
ROMBBatt
Low
PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad.
Failing device is reseated/replaced/repaired.
Yes
Any
W1228
ROMBBatt< 24 hr
Low
This is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.
Battery charges to > 24 hours of sustained charge.
Yes
Any
E1214
1.5VPwrGd
High
1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1215
1.8VPwrGd
High
1.8 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1216
3.3VPwrGd
High
3.3 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1217
5VPwrGd
High
5 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1218
PCIRsr5VPwrGd
High
PCI Riser 5 V voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1219
BackplanePwrGd
High
Backplane voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1221
Flex BayPwrGd
High
Flex Bay voltage regulator power good has failed.
AC Cycle or SEL clear
Yes
Any
E1222
VCACHE #PwrGd
High
VCACHE # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1223
VRM #PwrGd
High
VRM # voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1225
ESB 1.5VPwrGd
High
ESB 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1226
PCIRsr1.5VPwrGd
High
PCI Riser 1.5 VV voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1227
LinearPwrGd
High
Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.
AC Cycle or SEL clear
Yes
Any
E1228
0.9VPwrGd
High
Memory VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E1229
CPU # VCORE
High
Processor # VCORE voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122A
CPU VTTPwrGd
High
Processor VTT voltage regulator has failed.
AC Cycle or SEL clear
Yes
Any
E122B
0.9 V Over Voltage
High
0.9 V regulator voltage has exceeded the allowable voltage range.
AC Cycle or SEL clear
Yes
Any
E122C
CPU Power Fault
High
A voltage regulator failure was detected when the processor regulator(s) was enabled.
AC Cycle or SEL clear
Yes
Any
Fans - Message Code: "x13xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1310
RPM Fan ##
Low
RPM of fan ## is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #A
Low
RPM of fan A in the # module is outside of the intended operating range.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #B
Low
Same as above except for fan B of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #C
Low
Same as above except for fan C of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1311
RPM Fan Mod #D
Low
Same as above except for fan D of module #.
Fan RPM reading returns to a point inside of the intended operating range.
Yes
Any
E1313
Fan Redundancy
Low
The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.
Fan redundancy is regained, which requires all fans to be operating within the intended operating range.
Yes
Any
Processors - Message Code: "x14xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1410
CPU # IERR
High
Processor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR.
AC Cycle or SEL clear
Yes
Any
E1414
CPU #Thermtrip
High
Processor # has encountered a Thermtrip(over-temperature) event.
AC Cycle or SEL clear
Yes
Any
E1418
CPU # Presence
High
Processor # is missing/bad and the system is in an unsupported configuration.
AC Cycle or SEL clear
Yes
Pre-POST
E141C
CPU Mismatch
High
Processors are not compatible as defined by Dell .System is in an unsupported configuration.
AC Cycle or SEL clear
Yes
Pre-POST
E141F
CPU Protocol
High
BIOS has reported a processor protocol error.
AC Cycle or SEL clear
Yes
POST, After POST
E1420
CPU Bus PERR
High
BIOS has reported a processor bus PERR (parity error).
AC Cycle or SEL clear
Yes
POST, After POST
E1421
CPU Init
High
BIOS has reported a processor initialization error.
AC Cycle or SEL clear
Yes
POST, After POST
E1422
CPU MachineChk
High
BIOS has reported a machine check error.
AC Cycle or SEL clear
Yes
POST, After POST
System Memory - Message Code: "x21xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E2110
MBECrdx DIMM ## & ##
High
One of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.
AC Cycle or SEL clear
Yes
POST, After POST
E2111
SBE Log DisableCrdx DIMM ##
High
BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z.
System reset
Yes
POST, After POST
E2112
MemSpareCrdx DIMM ##
High
BIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.
System reset
Yes
POST, After POST
E2113
Mem Mirror Crd x DIMM ## & ##
High
BIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.
System reset
Yes
POST, After POST
I2114
MemRaid
Low
BIOS Memory RAID Bank
User action, sensor return to normal
Yes
Any
I2115
MemAdded Card x
Low
Memory has been added while the system is running.
AC Cycle or SEL clear
Yes
Any
I2116
MemRemoved
Low
Memory has been removed while the system is running.
AC Cycle or SEL clear
Yes
Any
E2117
MemHot Plug
Low
Memory hot-plug operation has failed.
AC Cycle or SEL clear
Yes
Any
E2118
Fatal NBMemCRC
High
Northbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST
E2119
Fatal SBMemCRC
High
FBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.
AC Cycle or SEL clear
Yes
POST, After POST
Power Supplies - Message Code: "x16xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1610
PS # Missing
Low
Power supply # was removed or is missing from the system.
Failing device is reseated/replaced/repaired.
Yes
Any
E1614
PS # Status
Low
Power supply # has failed.
Failing device is reseated/replaced/repaired.
Yes
Any
E1618
PS # Predictive
Low
Power supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).
Failing device is reseated/replaced/repaired.
Yes
Any
E161C
PS # Input Lost
Low
Power supply # is attached to the system but has lost its AC/DC input.
Failing device is reseated/replaced/repaired.
Yes
Any
E1620
PS #Input Range
Low
Power supply #'s AC/DC input is outside of the allowable range.
Failing device is reseated/replaced/repaired.
Yes
Any
E1624
PS Redundancy
Low
The power supply subsystem is no longer redundant. If the last supply fails the system will go down.
Failing device is reseated/replaced/repaired.
Yes
Any
E1625
PS AC Current
Low
The power supply input power is above the allowed amount for the power supply.
Failing device is reseated/replaced/repaired.
Yes
Any
BIOS - Message Code: "x17xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1710
I/O ChannelChk
High
BIOS has reported an I/O channel check.
AC Cycle or SEL clear
Yes
POST, After POST
E1711
PCI PERR B## D## F##
High
BIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E1711
PCI PERR Slot #
High
BIOS has reported PCI parity error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
E1712
PCI SERR B## D## F##
High
BIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E1712
PCI SERR Slot #
High
BIOS has reported a PCI system error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
E1714
Unknown Err
Low
BIOS has determined there has been an error in the system but is unable to determine its origin.
AC Cycle or SEL clear
Yes
POST, After POST
E171F
PCIE Fatal Err B## D## F##
High
BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.
AC Cycle or SEL clear
Yes
POST, After POST
E171F
PCIE Fatal Slot #
High
BIOS has reported a PCIe fatal error on a component that resides in slot #.
Same as above.
Same as above.
Same as above.
Hard Drives - Message Code: "x18xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1810
HDD ## Fault
Low
Hard drive ## has had a fault as determined by the SAS subsystem.
AC Cycle or SEL clear
Yes
POST, After POST
E1811
HDD ##RbldAbrt
Low
Drive ## has had its rebuild aborted.
AC Cycle or SEL clear
Yes
POST, After POST
E1812
HDD ## Removed
Low
Drive ## has been removed from the system.
System reset or device is reseated/replaced/repaired.
Yes
POST, After POST
Miscellaneous- Message Code: "x19xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
I1910
Intrusion
Low
The chassis lid has been removed.
Chassis lid is returned to the system.
Yes
Any
I1911
>3ERRsChkLog
N/A
User must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level.
Less than 3 events to display on the LCD.
No
Any
I1912
SEL Full
Med
System Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events.
AC Cycle or SEL clear
Yes
Any
E1913
CPU & Firmware Mismatch
Med
Current version of BMC firmware is incompatible with the Woodcrest processor.
AC Cycle or SEL clear
Yes
POST
BIOS Progress Codes - Message Code: N/A
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
N/A
POWER
N/A
0x01 -- System power-on.
N/A
No
Any
N/A
MCODE
N/A
0x02 -- CPU Microcode load.
N/A
No
Any
N/A
CINIT
N/A
0x03 -- Chipset Initialization.
N/A
No
Any
N/A
MEMC
N/A
0x04 -- Memory Configuration.
N/A
No
Any
N/A
SBIOS
N/A
0x05 -- BIOS shadow into memory.
N/A
No
Any
N/A
PINIT
N/A
0x06 -- Multiprocessor Initialization.
N/A
No
Any
N/A
START
N/A
0x07 -- POST processing start.
N/A
No
Any
N/A
SMM
N/A
0x08 -- System management interrupt (SMI) initialization.
N/A
No
Any
N/A
PCIEN
N/A
0x09 -- PCI Bus Enumeration & Video initialization.
N/A
No
Any
N/A
VIDEO
N/A
0x40 -- Display sign-on.
N/A
No
Any
N/A
PCIC
N/A
0x41 -- PCI Configuration.
N/A
No
Any
N/A
OS
N/A
0x7F -- Give control to OS.
N/A
No
Any
N/A
E2010
N/A
0x80 -- No memory installed in the system.
N/A
No
Any
N/A
E2011
N/A
0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.
N/A
No
Any
N/A
E2012
N/A
0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.
N/A
No
Any
N/A
E2013
N/A
0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.
N/A
No
Any
N/A
E2014
N/A
0x84 -- CMOS failure. CMOS'S RAM not working.
N/A
No
Any
N/A
E1215
N/A
0x05 -- DMA controller failure.
N/A
No
Any
N/A
E1116
N/A
0x80 -- Interrupt controller failure.
N/A
No
Any
N/A
E1217
N/A
0x07 -- Timer refresh failure.
N/A
No
Any
N/A
E1218
N/A
0x28 -- Programmable interval timer error.
N/A
No
Any
N/A
E0119
N/A
0x29 -- Parity error.
N/A
No
Any
N/A
E122A
N/A
0x2a -- SIO failure.
N/A
No
Any
N/A
E122B
N/A
0x00b0 -- Keyboard controller failure.
N/A
No
Any
N/A
E141C
N/A
0x3c -- System management interrupt (SMI) initialization failure.
N/A
No
Any
N/A
E.11
N/A
0xC4 -- BIOS shutdown test failure.
N/A
No
Any
N/A
E.11
N/A
0xC4 -- BIOS POST memory test failure. Could be the result of bad memory.
N/A
No
Any
N/A
E141F
N/A
0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.
N/A
No
Any
N/A
E0000
N/A
0xC4 -- CPU configuration failure. Check screen for the actual error message.
N/A
No
Any
N/A
E1221
N/A
0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.
N/A
No
Any
N/A
E1222
N/A
22x -- General failure after video. Check screen for the actual error message.
N/A
No
Any
BIOS Fatal Error Codes - Message Code: "x20xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E2010
No Memory
High
0x80 -- No memory installed in the system.
System reset
Yes
POST
E2011
MemConfigErr
High
0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.
System reset
Yes
POST
E2012
Unusable Memory
High
0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.
System reset
Yes
POST
E2013
Shadow BIOS Fail
High
0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.
System reset
Yes
POST
E2014
CMOS Fail
High
0x84 -- CMOS failure. CMOS'S RAM not working.
System reset
Yes
POST
E2015
DMA Controller
High
0x85 -- DMA controller failure.
System reset
Yes
POST
E2016
IntController
High
0x86 -- Interrupt controller failure.
System reset
Yes
POST
E2017
Timer Fail
High
0x87 -- Timer refresh failure.
System reset
Yes
POST
E2018
ProgTimer
High
0x88 -- Programmable interval timer error.
System reset
Yes
POST
E2019
Parity Error
High
0x89 -- Parity error.
System reset
Yes
POST
E201A
SIO Err
High
0x8A -- SIO failure.
System reset
Yes
POST
E201B
KybdController
High
0x8B -- Keyboard controller failure.
System reset
Yes
POST
E201C
SMI Init
High
0x8C -- System management interrupt (SMI) initialization failure.
System reset
Yes
POST
E201D
Shutdown Test
High
0xC0 -- BIOS shutdown test failure.
System reset
Yes
POST
E201E
POSTMemTest
High
0xC1 -- BIOS POST memory test failure. Could be the result of bad memory.
System reset
Yes
POST
E201F
DRACConfig
High
0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.
System reset
Yes
POST
E2020
CPUConfig
High
0xC3 -- CPU configuration failure. Check screen for the actual error message.
System reset
Yes
POST
E2021
Memory Population
High
0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.
System reset
Yes
POST
E2022
POST Fail
High
0xFE -- General failure after video. Check screen for the actual error message.
System reset
Yes
POST
Special Exceptions - Message Code: "x10xx"
Message Code
Message String
Message Priority
Message Comments
Minimum Action Required to Remove Message from LCD
Exists in SEL?
System Phase When Event Can Occur?
E1000
Failsafe, Call Support
Special
Check System Event Log for critical failure details.